BEA2000I
|
jobname BEA Connect TCP For IMS (vv.rr) has ended - RC = rc
|
|
|
Description:
|
This message is issued during termination just before BEA eLink TCP for IMS returns to OS/390.
jobname is the OS/390 job name assigned to BEA eLink TCP for IMS.
vv is the product version number.
rr is the product release number.
rc is a return code indicating the reason for termination. The most common return code is 24, indicating that termination occurred in response to a SHUTDOWN request.
|
|
|
Response:
|
BEA eLink TCP for IMS normally terminates in response to a SHUTDOWN request, in which case the return code is 24 and no special response is required.
If BEA eLink TCP for IMS terminates with a return code other than 24, termination is the result of an abnormal condition. In that case, there should be other messages that provide additional information about the reason for the termination.
|
|
BEA2001I
|
jobname BEA Connect TCP For IMS (vv.rr) starting
|
|
|
Description:
|
This message is issued when BEA eLink TCP for IMS begins execution.
jobname is the OS/390 job name assigned to BEA eLink TCP for IMS.
vv is the product version number.
rr is the product release number.
|
|
|
Response:
|
None required.
|
|
BEA2002I
|
jobname BEA Connect TCP For IMS (vv.rr) initialization complete
|
|
|
Description:
|
This message is issued when BEA eLink TCP for IMS has successfully completed initialization and is ready to begin normal processing.
jobname is the OS/390 job name assigned to BEA eLink TCP for IMS.
vv is the product version number.
rr is the product release number.
|
|
|
Response:
|
None required.
|
|
BEA2003I
|
BEA Connect TCP For IMS (vv.rr) is terminating (RSN=rc)
|
|
|
Description:
|
This message is issued when BEA eLink TCP for IMS begins the termination process (for example, in response to an operator SHUTDOWN command).
vv is the product version number.
rr is the product release number.
rc is a reason code indicating the reason for termination.
|
|
|
Response:
|
BEA eLink TCP for IMS normally terminates in response to a SHUTDOWN request, in which case the return code is 24 and no special response is required.
If BEA eLink TCP for IMS terminates with a return code other than 24, termination is the result of an abnormal condition. In that case, there should be other messages that provide additional information about the reason for the termination.
|
|
BEA2004E
|
Invalid IMS Client Request: description, Error(error-code), Reason(reason-code)
|
|
|
Description:
|
An IMS client transaction has issued a request that is invalid.
description is a text description of the error detected.
error-code is the error code. For a description of error codes issued by BEA eLink TCP for IMS, refer to "Error and Reason Codes."
reason-code is the reason code. For a description of reason codes issued by BEA eLink TCP for IMS, refer to "Error and Reason Codes."
|
|
|
Response:
|
Identify and correct the indicated problem.
|
|
BEA2005E
|
IMS Client Request for Service(service) failed: Requested service not defined
|
|
|
Description:
|
The requested service is not defined to BEA eLink TCP for IMS.
service is the specified service name.
|
|
|
Response:
|
The specified service is not defined in the BEA eLink TCP for IMS configuration file. Ensure that the correct local service name is being specified, and that the service is properly defined in the configuration file with the specified local service name.
|
|
BEA2006E
|
IMS Client Request for Service(service) failed: All outbound sessions busy
|
|
|
Description:
|
All available outbound sessions with remote systems offering the service are currently in use (and no additional sessions can be started due to session limits).
service is the specified service name.
|
|
|
Response:
|
Retry the request later. Increase the maximum number of outbound sessions defined for remote systems that offer the specified service.
|
|
BEA2007E
|
Client Request routing error: Service(service-name), RC(rc)
|
|
|
Description:
|
An internal error occurred while attempting to select a remote system and outbound session to process an IMS client request.
service-name is the specified service name.
rc is the return code returned by the GetServiceInfo() function.
|
|
|
Response:
|
Report the error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2008E
|
Operator command unrecognized - rejected
|
|
|
Description:
|
An operator command has been entered that is syntactically invalid.
|
|
|
Response:
|
Correct and re-enter the command.
|
|
BEA2009I
|
Operator request for SHUTDOWN accepted
|
|
|
Description:
|
BEA eLink TCP for IMS has recognized and accepted an operator request to initiate shutdown processing.
|
|
|
Action:
|
BEA eLink TCP for IMS begins the process of terminating.
|
|
|
Response:
|
None required.
|
|
BEA2010I
|
Initializing IMS interface
|
|
|
Description:
|
This message is issued during initialization to indicate that the interface with IMS (i.e., via the IMS message queue) is being initialized.
|
|
|
Response:
|
None required.
|
|
BEA2011E
|
Abnormal return from IMS function request - Status = ss
|
|
|
Description:
|
An IMS API call has returned an abnormal or unexpected status code.
function is the IMS function code: GU (Get Unique) GN (Get Next) CHNG (Change) ISRT (Insert) PURG (Purge) CHKP (Checkpoint).
ss is the status code from the program control block (PCB).
|
|
|
Response:
|
Identify the type of error and determine the reason for it. For example, the error may be the result of a temporary change in the IMS configuration.
|
|
BEA2012E
|
Open failed for Message Log: DDNAME(ddname)
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to open the message log.
ddname is the DDNAME of the message log dataset.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Verify that the correct DDNAME is coded in the JCL for BEA eLink TCP for IMS and that the message log dataset has the correct attributes.
|
|
BEA2013I
|
Initializing network (TCP/IP) interface
|
|
|
Description:
|
This message is issued during initialization to indicate that the TCP/IP network interface is being initialized. This includes starting a Listener session for each local gateway defined in the BEA eLink TCP for IMS configuration file.
|
|
|
Response:
|
None required.
|
|
BEA2014I
|
Terminating network (TCP/IP) interface
|
|
|
Description:
|
This message is issued during termination to indicate that the TCP/IP network interface is being terminated. This involves: - terminating active inbound sessions - terminating active outbound sessions - terminating Listener sessions
|
|
|
Response:
|
None required.
|
|
BEA2015I
|
ssss Inbound Sessions are no longer being accepted by LMID(lmid,L)
|
|
|
Description:
|
The Listener for the specified logical machine ID is being stopped; inbound TCP/IP connection requests are no longer accepted by this LMID.
ssss is the socket ID assigned to the Listener by TCP/IP.
lmid is the logical machine ID of the local gateway.
|
|
|
Response:
|
None required.
|
|
BEA2016I
|
Starting Listener for LMID(lmid,L), IP(ip-address), Port(port-number)
|
|
|
Description:
|
A Listener is being started for the local gateway to accept TCP/IP connection requests from remote systems.
lmid is the logical machine ID of the local gateway.
ip-address is the IP address at which TCP/IP connection requests are accepted. If an asterisk (*) appears, connection requests are accepted through any available network interface on the machine.
port-number is the port number at which TCP/IP connection requests are accepted.
|
|
|
Response:
|
None required.
|
|
BEA2017E
|
Unable to allocate Session Control Block for Listener
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage for an internal control block used to manage a Listener session.
|
|
|
Response:
|
This is an abnormal condition indicating a severe storage shortage or corruption of the storage allocation control blocks. It may be necessary to terminate BEA eLink TCP for IMS (preferably with a dump) to identify and correct the problem.
|
|
BEA2018I
|
ssss LMID(lmid,L) is accepting TCP/IP connection requests at IP(ip-address), Port(port-number)
|
|
|
Description:
|
A Listener was successfully started for a local gateway and is ready to accept inbound TCP/IP connection requests from remote systems.
ssss is the socket ID assigned to the Listener by TCP/IP.
lmid is the logical machine ID of the local gateway.
ip-address is the IP address at which TCP/IP connection requests are accepted. If an asterisk (*) appears, connection requests are accepted through any available network interface.
port-number is the port number on which TCP/IP connection requests are accepted.
|
|
|
Response:
|
None required.
|
|
BEA2019I
|
ssss Inbound TCP/IP connection request received for LMID(lmid,L) from IP(ip-address: host-name)
|
|
|
Description:
|
A TCP/IP connection request was received from a remote system for a local gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
ip-address is the IP address of the remote system making the request.
host-name is the network name of the remote system making the request. TCP/IP obtains this information from a domain name server or from a local /etc/hosts file. If the name of the remote host cannot be determined, "Unknown" is displayed.
|
|
|
Response:
|
None required.
|
|
BEA2020E
|
ssss Inbound TCP/IP connection request rejected: Session limit (max-sessions) exceeded
|
|
|
Description:
|
A TCP/IP connection request from a remote system was rejected because the local gateway is already operating at the specified maximum number of concurrent, inbound sessions.
ssss is the socket ID assigned to the connection by TCP/IP.
max-sessions is the maximum number of concurrent, active inbound sessions supported by the local gateway.
|
|
|
Response:
|
If necessary, increase the maximum number of inbound sessions for the local gateway (defined by the SESSIONS parameter in the GATEWAY TYPE=LOCAL statement).
|
|
BEA2021E
|
ssss Unable to allocate Session Control Block for Inbound Session
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage for an internal control block used to manage an inbound session.
ssss is the socket ID assigned to the connection by TCP/IP.
|
|
|
Response:
|
This is an abnormal condition indicating a severe storage shortage or corruption of the storage allocation control blocks. It may be necessary to terminate BEA eLink TCP for IMS (preferably with a dump) to identify and correct the problem.
|
|
BEA2022I
|
ssss Inbound TCP/IP connection accepted by LMID(lmid,L(port)) from R(ip-address:port)
|
|
|
Description:
|
An inbound TCP/IP connection from a remote system has been accepted by a local gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the port for logical machine ID of the local gateway accepting the connection.
port is the port for the local gateway accepting the connection.
ip-address:port is the IP address and port for the remote system making the connection.
|
|
|
Response:
|
None required.
|
|
BEA2023I
|
Requesting outbound TCP/IP connection with LMID(lmid,R) at IP(ip-address), Port(port-number)
|
|
|
Description:
|
The local gateway is attempting to establish an outbound TCP/IP connection with a remote system.
lmid is the logical machine ID of the remote gateway.
ip-address is the IP address of the remote gateway.
port-number is the port number of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2024I
|
ssss Unable to establish TCP/IP connection with LMID(lmid,R)
|
|
|
Description:
|
The local gateway failed to establish an outbound TCP/IP connection with a remote system.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2025E
|
ssss Received message length (rcvd-length) exceeds maximum allowed on session (max-length)
|
|
|
Description:
|
The local gateway received a gateway message whose length exceeds the maximum allowed for the session.
ssss is the socket ID assigned to the connection by TCP/IP.
rcvd-length is the length of the message received.
max-length is the maximum message length allowed on the session.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
This error can be caused by any of the following:
- The configurations of the local and/or remote gateways
may be incorrect or inconsistent with respect to the
maximum message length allowed. The maximum
message length of the local gateway is specified by the
MAXMSGLEN parameter on the GATEWAY
TYPE=LOCAL statement.
- The remote gateway may not be properly configured to
connect to an IMS gateway. In particular, the remote
gateway may be configured incorrectly to connect to a
CICS gateway.
- Some other TCP/IP application (i.e., not a BEA eLink
gateway) may be attempting to connect to the IP address
and port number used by BEA eLink TCP for IMS. Check
the configuration and verify that BEA eLink TCP for IMS
is not using an IP address and port number which are also
being used by another TCP/IP application.
|
|
BEA2026E
|
ssss Message header length (length) is not valid
|
|
|
Description:
|
The local gateway received a gateway message containing an invalid header length.
ssss is the socket ID assigned to the connection by TCP/IP.
length is the length of the message header received.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
This error may be caused by any of the following:
- The versions of the local and remote gateways may be
incompatible.
- Some other TCP/IP application (i.e., not a BEA eLink
gateway) may be attempting to connect to the IP address
and port number used by BEA eLink TCP for IMS. Check
the configuration and verify that BEA eLink TCP for IMS
is not using an IP address and port number which is also
being used by another TCP/IP application.
|
|
BEA2027E
|
ssss Message length (length) is not valid
|
|
|
Description:
|
The local gateway received a gateway message whose overall length is invalid (the total length is less than the length of the message header).
ssss is the socket ID assigned to the connection by TCP/IP.
length is the length of the gateway message received.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
Contact your BEA eLink TCP for IMS system programmer.
|
|
BEA2028E
|
ssss IMS Client Request timed out: LMID(lmid,R), Service(service)
|
|
|
Description:
|
An IMS client request was sent to a remote system for processing, but no response was received within a specified period of time.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
service is the remote name of the service requested (i.e., the name of the service as defined on the remote system).
|
|
|
Action:
|
BEA eLink TCP for IMS aborts the request and schedules the specified IMS response transaction with the appropriate return codes.
|
|
|
Response:
|
The remote system may be experiencing problems, or may be extremely busy. An adjustment to the time out value may resolve this problem.
|
|
BEA2029E
|
ssss Allocation failed for buffer (size = buffer-size)
|
|
|
Description:
|
BEA eLink TCP for IMS is unable to allocate a buffer of the specified size for a gateway message.
ssss is the socket ID assigned to the connection by TCP/IP (this field is blank if there is no associated connection).
buffer-size is the size of the requested buffer.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
Assuming a reasonable buffer size, this is an abnormal condition indicating a severe storage shortage or corruption of the storage allocation control blocks. It may be necessary to terminate BEA eLink TCP for IMS (preferably with a dump) to identify and correct the problem.
|
|
BEA2030E
|
ssss IMS Server Request failed - Invalid IMS transaction code: Service(service-name)
|
|
|
Description:
|
BEA eLink TCP for IMS received an abnormal return from IMS (PCB Status Code = "A1") while attempting to insert a server request message into the IMS message queue.
ssss is the socket ID assigned to the connection by TCP/IP.
service-name is the name of the requested service (i.e., the IMS transaction code for the server transaction).
|
|
|
Action:
|
The request fails. This message is also returned to the remote gateway as part of a negative response to the request.
|
|
|
Response:
|
The requested service name must be the (correct) IMS transaction code for the server transaction that processes the request. Check the remote configuration and verify that a valid IMS transaction name is specified as the remote service name.
|
|
BEA2031I
|
ssss Shutdown requested by client transaction: Type(type)
|
|
|
Description:
|
A client transaction requested a shutdown of the IMS gateway. Note that this request can be made either by a remote (e.g., BEA TUXEDO) client or an IMS server transaction if CLIENTSHUTDOWN is set to Yes.
ssss is the socket ID assigned to the connection by TCP/IP.
type is the type of shutdown requested: STOP - Normal shutdown DUMP - User 3166 abend with dump
|
|
|
Action:
|
BEA eLink TCP for IMS initiates shutdown processing.
|
|
|
Response:
|
Assuming that this is a valid request, no response is required.
|
|
BEA2032E
|
ssss IMS Server Request (size=size) exceeds maximum supported IMS message length (max-length)
|
|
|
Description:
|
BEA eLink TCP for IMS received a server request which is too large to be formatted into a single IMS message segment for insertion into the IMS message queue.
ssss is the socket ID assigned to the connection by TCP/IP.
size is the length of the request message received.
max-length is the maximum supported length of an IMS message segment.
|
|
|
Action:
|
The request fails.
|
|
|
Response:
|
Server requests are limited by the maximum supported IMS message segment length.
|
|
BEA2033E
|
Logging IMS Server Response: mmddyyyy.hhmmss.nnnnnn (reason)
|
|
|
Description:
|
BEA eLink TCP for IMS is unable to correlate a response message returned by an IMS server transaction with a pending, active request. Each server request and response message is identified by a timestamp consisting of the date and time that BEA eLink TCP for IMS was started and a unique serial number:
mm month (1-12) dd day (1-31) yyyy year hh hour (0-23) mm minute (0-59) ss second (0-59) nnnnnn serial number reason specifies the reason that the response is being logged.
|
|
|
Action:
|
The response message is logged in the server response log dataset.
|
|
|
Response:
|
If the reason is "Server Request not found", one of the following occurred:
- BEA eLink TCP for IMS was restarted after the server
request was sent to IMS but before the response was
received. This message may be issued following a restart
of BEA eLink TCP for IMS if server requests were in
progress at the time BEA eLink TCP for IMS was
terminated.
- The TCP/IP connection with the remote gateway was lost
after the server request was sent to IMS but before the
response was received.
- A server request timed out and was aborted (either by the
local or the remote gateway) before the response was
received from IMS.
|
|
|
Response:
|
If the reason is "No response was expected", it indicates that an IMS server transaction issued a response to a request for which a response was not required. Correct the IMS server transaction. One other possible cause for this error is that BEA eLink TCP for IMS was unable to identify an IMS client request and processed it as if it were an IMS server response. This can happen if an IMS client transaction improperly initializes the BEA Client request header by failing to initialize the BEA-RESERVED1 field (BEA_Reserved1 in the C header file) to binary zero (low values).
|
|
BEA2034E
|
ssss Invalid or unsupported request received by LMID(lmid,L): Opcode(opcode)
|
|
|
Description:
|
BEA eLink TCP for IMS received a gateway message from a remote gateway containing an invalid or unsupported request type.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is theological machine ID of the local gateway receiving the request.
opcode is a numeric value identifying the request type.
|
|
|
Action:
|
The session is terminated. This message is also sent to the remote gateway as part of a negative response to the request.
|
|
|
Response:
|
The local and remote gateways may be incompatible (different versions).
|
|
BEA2035E
|
Unable to add service service-name, maximum service count reached.
|
|
|
Description:
|
The maximum number of dynamically added services has been reached.
|
|
|
Action:
|
The ADD SERVICE operator command is rejected.
|
|
|
Response:
|
The service cannot be added dynamically. The BEA eLink TCP for IMS gateway must be stopped and restarted before additional services can be added dynamically.
|
|
BEA2036I
|
ssss CONNECT request received by LMID(lmid,L)
|
|
|
Description:
|
BEA eLink TCP for IMS received a CONNECT request from a remote gateway. A CONNECT request is issued to establish an inbound session with the local gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Response:
|
None required.
|
|
BEA2037I
|
ssss CONNECT request accepted by LMID(lmid,L)
|
|
|
Description:
|
BEA eLink TCP for IMS accepted a CONNECT request from a remote gateway. An inbound session has been established.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Response:
|
None required.
|
|
BEA2038I
|
Reserved for future use by BEA Connect TCP for IMS.
|
|
BEA2039E
|
ssss CONNECT request rejected by LMID(lmid,L): Not Authorized
|
|
|
Description:
|
The local gateway rejected a CONNECT request from a remote gateway because the account ID and/or password presented is not correct.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway.
|
|
|
Action:
|
The session is terminated. This message is also returned to the remote gateway as part of a negative response to the CONNECT request.
|
|
|
Response:
|
Check the respective configurations of the local and remote gateways to verify that they are consistent with respect to account ID and/or password. If the local gateway definition specifies that no account ID and/or password are to be used (by coding an asterisk for the account ID and/or password), the remote gateway must present a blank (i.e., spaces) account ID and/or password.
|
|
BEA2040I
|
ssss SHUTDOWN request received by LMID(lmid,L)
|
|
|
Description:
|
BEA eLink TCP for IMS received a SHUTDOWN request from a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Action:
|
BEA eLink TCP for IMS initiates termination processing.
|
|
|
Response:
|
None required.
|
|
BEA2041I
|
ssss DISCONNECT request received by LMID(lmid,L)
|
|
|
Description:
|
BEA eLink TCP for IMS received a DISCONNECT request from a remote gateway. A DISCONNECT request may be sent by a remote gateway to logically terminate a session.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Action:
|
BEA eLink TCP for IMS terminates the inbound session with the remote gateway. Note, however, that the TCP/IP connection is not affected and remains open. The remote gateway may issue a subsequent CONNECT request to establish a new inbound session, or it may close the TCP/IP connection at its option.
|
|
|
Response:
|
None required.
|
|
BEA2042I
|
ssss DISCONNECT request accepted by LMID(lmid,L)
|
|
|
Description:
|
BEA eLink TCP for IMS accepted a DISCONNECT request received from a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Action:
|
This message is also returned to the remote gateway as part of a positive response to the DISCONNECT request.
|
|
|
Response:
|
None required.
|
|
BEA2043I
|
Inbound (request/response) for LMID(lmid,L)
|
|
|
Description:
|
A network message was received.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Action:
|
None.
|
|
|
Response:
|
None required. This message is used only when MSGLEVEL is set to DEBUG(10).
|
|
BEA2044I
|
ssss PING request received by LMID(lmid,L)
|
|
|
Description:
|
BEA eLink TCP for IMS received a PING request from a remote gateway. A PING request may be sent by a remote gateway to verify that a logical session exists and that the partner gateway is operative.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Response:
|
None required.
|
|
BEA2045I
|
PING response: jobname BEA Connect TCP For IMS (vv.rr)
|
|
|
Description:
|
This message is returned to the remote gateway by BEA eLink TCP for IMS in response to a PING request. This message is not logged.
jobname is the OS/390 job name assigned to BEA eLink TCP for IMS.
vv is the product version number.
rr is the product release number.
|
|
|
Response:
|
None required.
|
|
BEA2046I
|
ssss COMMAND received by LMID(lmid,L)
|
|
|
Description:
|
BEA eLink TCP for IMS has received a command from a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
|
|
|
Response:
|
The COMMAND request is not currently supported by BEA eLink TCP for IMS and should not be sent by a remote gateway. (See ID: BEA2047E).
|
|
BEA2047E
|
ssss Command rejected by LMID(lmid,L): Remote commands are not supported
|
|
|
Description:
|
BEA eLink TCP for IMS does not currently support commands sent by remote gateways.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway.
|
|
|
Action:
|
BEA eLink TCP for IMS ignores the request. This message is also returned to the remote gateway as part of a negative response to the COMMAND request.
|
|
|
Response:
|
The remote gateway should not be sending commands. Check the configuration and version of the remote gateway to determine why this is occurring.
|
|
BEA2048I
|
Allocating Buffer (size=n)
|
|
|
Description:
|
An internal storage buffer was allocated.
|
|
|
Action:
|
None.
|
|
|
Response:
|
None required. This message is used only when MSGLEVEL is set to DEBUG(10).
|
|
BEA2049E
|
ssss Protocol error detected by LMID(lmid,L) on Inbound Session: Request(request), State(state)
|
|
|
Description:
|
BEA eLink TCP for IMS received a request from a remote gateway, but the session is currently in a state which is inconsistent with the request.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the local gateway receiving the request.
request is the type of request received: CONNECT, DISCONNECT, etc.
state is a numeric value corresponding to the current state of the session, as viewed by BEA eLink TCP for IMS.
|
|
|
Action:
|
BEA eLink TCP for IMS takes no specific action. However, subsequent errors (including additional protocol errors) can occur, which likely leads to termination of the session. This message is also returned to the remote gateway as part of a negative response to the request.
|
|
|
Response:
|
This error can occur if two gateways become "out of sync" on a session with respect to their respective states. If this error occurs frequently or persistently, notify the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2050I
|
IMS Host hostname has been added.
|
|
|
Description:
|
The ADD HOST operator command has completed successfully.
|
|
|
Action:
|
None.
|
|
|
Response:
|
None required.
|
|
BEA2051E
|
ssss Invalid or unsupported response received from LMID(lmid,R): Opcode(opcode)
|
|
|
Description:
|
BEA eLink TCP for IMS received a response message from a remote gateway on an outbound session that cannot be identified (that is, the Opcode in the BEA eLink message header is not valid).
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
opcode is the numeric value of the Opcode in the Message Header.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
If this error occurs, notify the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2052I
|
ssss Issuing CONNECT request for LMID(lmid,R)
|
|
|
Description:
|
BEA eLink TCP for IMS is requesting an outbound session with a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2053E
|
ssss CONNECT request rejected by LMID(lmid,R): GWError(gwerror), GWMsg(gwmsg)
|
|
|
Description:
|
BEA eLink TCP for IMS received a negative response to a CONNECT request to establish an outbound session with a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
gwerror is the gateway error code returned by the remote gateway.
gwmsg is the gateway error message returned by the remote gateway.
|
|
|
Action:
|
The CONNECT request fails and the TCP/IP connection with the remote gateway is terminated.
|
|
|
Response:
|
Refer to the documentation for the remote gateway for information about the reason for the error. Also, consult the remote gateway's log file for additional information.
|
|
BEA2054I
|
ssss CONNECT request accepted by LMID(lmid,R)
|
|
|
Description:
|
BEA eLink TCP for IMS has received a positive response to a CONNECT request to establish an outbound session with a remote gateway. The session is established and is ready to process requests.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2055I
|
ssss Issuing DISCONNECT for LMID(lmid,R)
|
|
|
Description:
|
BEA eLink TCP for IMS is ending an outbound session with a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2056E
|
ssss DISCONNECT rejected by LMID(lmid,R): GWError(gwerror), GWMsg(gwmsg)
|
|
|
Description:
|
BEA eLink TCP for IMS received a negative response to a DISCONNECT request to end an outbound session with a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
gwerror is the gateway error code returned by the remote gateway.
gwmsg is the gateway error message returned by the remote gateway.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
Refer to the documentation for the remote gateway for information about the reason for the error. Also, consult the remote gateway's log file for additional information.
|
|
BEA2057I
|
ssss DISCONNECT accepted by LMID(lmid,R)
|
|
|
Description:
|
BEA eLink TCP for IMS received a positive response to a DISCONNECT request to end an outbound session with a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2058I
|
ssss Sending PING request to LMID(lmid,R)
|
|
|
Description:
|
BEA eLink TCP for IMS is sending a PING request to a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2059E
|
ssss PING request rejected by LMID(lmid,R): GWError(gwerror), GWMsg(gwmsg)
|
|
|
Description:
|
BEA eLink TCP for IMS received a negative response to a PING request sent to a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
gwerror is the gateway error code returned by the remote gateway.
gwmsg is the gateway error message returned by the remote gateway.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
Refer to the documentation for the remote gateway for information about the reason for the error. Also, consult the remote gateway's log file for additional information.
|
|
BEA2060I
|
ssss PING response from LMID(lmid,R): response
|
|
|
Description:
|
BEA eLink TCP for IMS received a positive response to a PING request sent to a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway. response is the text of the response message returned by the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2061I
|
ssss Sending command to LMID(lmid,R)
|
|
|
Description:
|
BEA eLink TCP for IMS is sending a command to a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
|
|
|
Response:
|
None required.
|
|
BEA2062E
|
ssss COMMAND rejected by LMID(lmid,R): GWError(gwerror), GWMsg(gwmsg)
|
|
|
Description:
|
BEA eLink TCP for IMS received a negative response to a command sent to a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
gwerror is the gateway error code returned by the remote gateway.
gwmsg is the gateway error message returned by the remote gateway.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
Refer to the documentation for the remote gateway for information about the reason for the error. Also, consult the remote gateway's log file for additional information.
|
|
BEA2063E
|
ssss Unable to allocate buffer for IMS Client Request (size=buffer-size)
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage for an internal buffer required to process an IMS client request.
ssss is the socket ID assigned to the connection by TCP/IP.
buffer-size is the size of the required buffer.
|
|
|
Response:
|
This is an abnormal condition indicating a severe storage shortage or corruption of the storage allocation control blocks. It may be necessary to terminate BEA eLink TCP for IMS (preferably with a dump) to identify and correct the problem.
|
|
BEA2064E
|
ssss IMS Client Request sent to LMID(lmid,R) failed: GWError(gwerror), GWMsg(gwmsg)
|
|
|
Description:
|
BEA eLink TCP for IMS received a negative response to an IMS client request sent to a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the remote gateway.
gwerror is the gateway error code returned by the remote gateway.
gwmsg is the gateway error message returned by the remote gateway.
|
|
|
Action:
|
The specified IMS client response transaction is scheduled with the appropriate return codes.
|
|
|
Response:
|
Refer to the documentation for the remote gateway for information about the reason for the error. Also, consult the remote gateway's log file for additional information.
|
|
BEA2065E
|
ssss State error on inout Session: LMID(lmid,type), Request(request), State(state)
|
|
|
Description:
|
BEA eLink TCP for IMS attempted to execute an operation against a session which is not currently in a state consistent with the requested operation.
ssss is the socket ID assigned to the connection by TCP/IP.
inout session type: inbound or outbound.
lmid is the logical machine ID of the gateway.
type is the gateway type: L (local) or R (remote).
request is the request type: CONNECT, DISCONNECT, etc.
state describes the current state of the session.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
Refer this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2066E
|
Unable to allocate Session Control Block for Outbound Session
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage for an internal control block required to manage an outbound session.
|
|
|
Response:
|
This is an abnormal condition indicating a severe storage shortage or corruption of the storage allocation control blocks. It may be necessary to terminate BEA eLink TCP for IMS (preferably with a dump) to identify and correct the problem.
|
|
BEA2067I
|
ssss TCP/IP connection closed by session partner
|
|
|
Description:
|
BEA eLink TCP for IMS was notified that a TCP/IP connection with a remote system was closed by the session partner.
ssss is the socket ID assigned to the connection by TCP/IP.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
None required.
|
|
BEA2068I
|
ssss TCP/IP connection reset
|
|
|
Description:
|
BEA eLink TCP for IMS was notified that a connection with a remote system was reset. A reset occurs when the connection is hard-closed (i.e., closed without first issuing a TCP/IP shutdown request).
ssss is the socket ID assigned to the connection by TCP/IP.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
None required.
|
|
BEA2069E
|
ssss Length error on socket read
|
|
|
Description:
|
TCP/IP reported an illogical length read from a connection; for example, the length reported was greater than the actual length requested.
ssss is the socket ID assigned to the connection by TCP/IP.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
This error may indicate a problem with TCP/IP for OS/390.
|
|
BEA2070E
|
ssss Abnormal return from TCP/IP API request: fcn(function), rc(rc), errno(errno)
|
|
|
Description:
|
BEA eLink TCP for IMS received an abnormal return from a TCP/IP socket operation.
ssss is the socket ID assigned to the connection by TCP/IP.
function is the TCP/IP API function called: read, write, etc.
rc is the TCP/IP return code (usually -1).
errno is the TCP/IP errno value returned.
|
|
|
Action:
|
The session is terminated.
|
|
|
Response:
|
Consult the IBM TCP/IP for OS/390 documentation for a description of possible errno values and their meanings.
|
|
BEA2071I
|
ssss Session termination in progress (RSN=reason)
|
|
|
Description:
|
BEA eLink TCP for IMS has initiated termination of a session with a remote gateway.
ssss is the socket ID assigned to the connection by TCP/IP.
reason is a numeric value indicating the reason the session is being terminated. Some typical reason codes are: 12 A socket error occurred.
16 The connection was closed by the session partner. 20 An internal gateway request (such as CONNECT) timed out. 24 BEA eLink TCP for IMS is terminating in response to a SHUTDOWN request. 28 Session limit exceeded (a new session cannot be started). 60 A session protocol error occurred.
|
|
|
Response:
|
This action typically occurs as the result of a session-related error condition (identified by the reason code), or in conjunction with a SHUTDOWN request. If a reason code other than one of those previously listed is given, the error should be reported to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2072I
|
ssss TCP/IP connection closed
|
|
|
Description:
|
As part of the session termination process, BEA eLink TCP for IMS successfully closed the TCP/IP connection. ssss is the socket ID assigned to the connection by TCP/IP.
|
|
|
Response:
|
None required.
|
|
BEA2073I
|
ssss Session termination complete
|
|
|
Description:
|
A session was successfully terminated by BEA eLink TCP for IMS.
ssss is the socket ID assigned to the connection by TCP/IP.
|
|
|
Response:
|
None required.
|
|
BEA2074E
|
Error writing to Server Response Log File
|
|
|
Description:
|
BEA eLink TCP for IMS received an abnormal return attempting to write a record to the server response log file.
|
|
|
Response:
|
Check the server response log file to ensure that it is allocated with the correct dataset attributes, allocated using the correct DDNAME, and is not full or experiencing I/O errors.
|
|
BEA2075E
|
Open failed for server response log file: DDNAME(ddname)
|
|
|
Description:
|
BEA eLink TCP for IMS is not able to open the Server Response Log File.
ddname is the DDNAME used by BEA eLink TCP for IMS to open the dataset.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Check the server response log file to ensure that it is allocated with the correct dataset attributes and is allocated using the correct DDNAME as shown.
|
|
BEA2076E
|
ssss IMS Server Request received with previous request pending (timeout assumed)
|
|
|
Description:
|
BEA eLink TCP for IMS received an IMS server request from a remote gateway, but a prior request is still pending (i.e., currently being serviced by IMS).
ssss is the socket ID assigned to the connection by TCP/IP.
|
|
|
Action:
|
BEA eLink TCP assumes that the remote gateway timed out while waiting for a response to the previous request. Therefore, the previous request (currently being serviced by IMS) is aborted (discarded) and BEA eLink TCP for IMS begins processing the new request.
|
|
|
Response:
|
This error can occur when a remote gateway cancels a previously sent request (i.e., due to timeout) and immediately sends another request.
|
|
BEA2077E
|
ssss Pending IMS Server Request for Service(service) aborted
|
|
|
Description:
|
BEA eLink TCP for IMS aborted processing of the current server request.
ssss is the socket ID assigned to the connection by TCP/IP.
service is the name of the IMS server transaction scheduled to process the current request.
|
|
|
Action:
|
The current request is discarded and the session is ready to accept a new request.
|
|
|
Response:
|
None required.
|
|
BEA2078E
|
ssss IMS Server Request timed out: Service(service)
|
|
|
Description:
|
An IMS server request requiring a response was being processed by IMS, but no response was received within a specified period of time.
ssss is the socket ID assigned to the connection by TCP/IP.
service is the name of the IMS server transaction scheduled to process the request.
|
|
|
Action:
|
The request is aborted. This message is also returned to the remote gateway as part of a negative response to the request.
|
|
|
Response:
|
Check the IMS server transaction (service) that processes the request to make sure that it is not stopped or has an unusually high backlog.
|
|
BEA2079E
|
Client Response failed: Sense Code=sc Reason=reason
|
|
|
Description:
|
A response to a client request was rejected by OTMA.
sc is the sense code.
reason is a numeric value indicating the reason for the response failure.
|
|
|
Action:
|
The response is logged.
|
|
|
Response:
|
Consult the IMS Open Transaction Manager Access Guide to determine the cause of the error.
|
|
BEA2080E
|
Malloc failed for parse work area
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage for an internal work area used to parse the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Report this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2081I
|
IOPCB after CHKP Call:
|
|
|
Description:
|
Displays the contents of the IOPCB after a CHKP DLI call.
|
|
|
Action:
|
None.
|
|
|
Response:
|
None required. This message is used only when MSGLEVEL is set to DEBUG(10).
|
|
BEA2082E
|
Missing LMID option for REMOTE GATEWAY
|
|
|
Description:
|
A required keyword parameter (LMID) was omitted from a GATEWAY TYPE=REMOTE statement in the configuration File.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2083E
|
Missing HOSTADDR option for REMOTE GATEWAY
|
|
|
Description:
|
A required keyword parameter (HOSTADDR) was omitted from a GATEWAY TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2084E
|
Missing PORT option for REMOTE GATEWAY
|
|
|
Description:
|
A required keyword parameter (PORT) was omitted from a GATEWAY TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2085E
|
NAME option is invalid for REMOTE GATEWAY
|
|
|
Description:
|
An invalid keyword parameter (NAME) was specified on a GATEWAY TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2086E
|
TIMEOUT option is invalid for REMOTE GATEWAY
|
|
|
Description:
|
An invalid keyword parameter (TIMEOUT) was specified on a GATEWAY TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2087E
|
Cannot malloc for Remote Host
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage for an internal control block used to manage a remote gateway.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Report this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2088E
|
Missing LMID option for LOCAL GATEWAY
|
|
|
Description:
|
A required keyword parameter (LMID) was omitted from a GATEWAY TYPE=LOCAL statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2089E
|
Missing HOSTADDR option for LOCAL GATEWAY
|
|
|
Description:
|
A required keyword parameter (HOSTADDR) was omitted from a GATEWAY TYPE=LOCAL statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2090E
|
Missing PORT option for LOCAL GATEWAY
|
|
|
Description:
|
A required keyword parameter (PORT) was omitted from a GATEWAY TYPE=LOCAL statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2091E
|
Missing ACCOUNT option for LOCAL GATEWAY
|
|
|
Description:
|
A required keyword parameter (ACCOUNT) was omitted from a GATEWAY TYPE=LOCAL statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2092E
|
Missing PASSWORD option for LOCAL GATEWAY
|
|
|
Description:
|
A required keyword parameter (PASSWORD) was omitted from a GATEWAY TYPE=LOCAL statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2093E
|
NAME option is invalid for LOCAL GATEWAY
|
|
|
Description:
|
An invalid keyword parameter (NAME) was specified on a GATEWAY TYPE=LOCAL statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2094E
|
TIMEOUT option is invalid for LOCAL GATEWAY
|
|
|
Description:
|
An invalid keyword parameter (TIMEOUT) was specified on a GATEWAY TYPE=LOCAL statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2095E
|
Cannot malloc for Local Host
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage for an internal control block used to manage the local gateway.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Report this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2096E
|
Missing LMID option for REMOTE SERVICE
|
|
|
Description:
|
A required keyword parameter (LMID) was omitted from a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2097E
|
HOSTADDR option is invalid for REMOTE SERVICE
|
|
|
Description:
|
An invalid keyword parameter (HOSTADDR) was specified on a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2098E
|
PORT option is invalid for REMOTE SERVICE
|
|
|
Description:
|
An invalid keyword parameter (PORT) was specified on a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2099E
|
ACCOUNT option is invalid for REMOTE SERVICE
|
|
|
Description:
|
An invalid keyword parameter (ACCOUNT) was specified on a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2100E
|
PASSWORD option is invalid for REMOTE SERVICE
|
|
|
Description:
|
An invalid keyword parameter (PASSWORD) was specified on a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2101E
|
MAXMSGLEN option is invalid for REMOTE SERVICE
|
|
|
Description:
|
An invalid keyword parameter (MAXMSGLEN) was specified on a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2102E
|
SESSIONS option is invalid for REMOTE SERVICE
|
|
|
Description:
|
An invalid keyword parameter (SESSIONS) was specified on a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2103E
|
Missing NAME option for REMOTE SERVICE
|
|
|
Description:
|
A required keyword parameter (NAME) was omitted from a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2104E
|
Missing TIMEOUT option for REMOTE SERVICE
|
|
|
Description:
|
A required keyword parameter (TIMEOUT) was omitted from a SERVICE TYPE=REMOTE statement in the configuration file.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the problem and restart BEA eLink TCP for IMS.
|
|
BEA2105E
|
Cannot malloc for Work Service
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage used to process remote service definitions.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Report this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2106E
|
Cannot malloc for CurrWorkSer Info
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage used to process remote service definitions.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Report this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2107E
|
The command lines which are in error are: text
|
|
|
Description:
|
When a syntax error is detected during processing of the configuration file, BEA eLink TCP for IMS displays the lines containing the error.
text is the line containing the text in error.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the error and restart BEA eLink TCP for IMS.
|
|
BEA2108E
|
Cannot malloc for ServiceKeys
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to allocate storage used to process remote service definitions.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Report this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2109E
|
Could not find LMID [lmid] for Service [service]
|
|
|
Description:
|
The logical machine ID (LMID) specified on a SERVICE TYPE=REMOTE statement could not be matched with a GATEWAY TYPE=REMOTE statement specifying the same (matching) LMID in the configuration file.
lmid is the logical machine ID specified in the SERVICE TYPE=REMOTE statement.
service is the local service name specified in the SERVICE TYPE=REMOTE statement.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Each Remote Service must be associated with a particular remote gateway (identified by a unique logical machine ID) that provides the service. Check the GATEWAY TYPE=REMOTE and SERVICE TYPE=REMOTE statements to verify that they specify the same logical machine ID. Correct any errors and restart BEA eLink TCP for IMS.
|
|
BEA2110E
|
Syntax error in configuration file, line line-no
|
|
|
Description:
|
A syntax error was detected during processing of the configuration file.
line-no is the line number of the line containing the syntax error.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the error and restart BEA eLink TCP for IMS.
|
|
BEA2111E
|
Line in error: text
|
|
|
Description:
|
This message is displayed in conjunction with message BEA2110E.
text is the line containing the text in error.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Correct the error and restart BEA eLink TCP for IMS.
|
|
BEA2112E
|
Open failed for configuration file: DDNAME(ddname)
|
|
|
Description:
|
BEA eLink TCP for IMS was unable to open the configuration file.
ddname is the logical dataset name of the configuration file dataset.
|
|
|
Action:
|
Initialization fails and BEA eLink TCP for IMS terminates.
|
|
|
Response:
|
Verify that the correct DDNAME is coded in the JCL for BEA eLink TCP for IMS and that the configuration file dataset has the correct attributes.
|
|
BEA2113I
|
jobname BEA Connect TCP For IMS (vv.rr) ready
|
|
|
Description:
|
This message is issued by BEA eLink TCP for IMS in conjunction with an outstanding WTOR which can be used to enter operator commands.
jobname is the OS/390 job name assigned to BEA eLink TCP for IMS.
vv is the product version number.
rr is the product release number.
|
|
|
Response:
|
None required. You can reply to the associated WTOR to enter an operator command for BEA eLink TCP for IMS.
|
|
BEA2114I
|
ssss Session TIMEOUT detected on LMID(lmid,type)
|
|
|
Description:
|
This message is issued by BEA eLink TCP for IMS when an IDLE TIMEOUT has occurred.
ssss is the socket ID assigned to the connection by TCP/IP.
lmid is the logical machine ID of the gateway.
type is the gateway type: L (local) or R (remote).
|
|
|
Response:
|
Refer this error to the systems programmer responsible for BEA eLink TCP for IMS.
|
|
BEA2115I
|
Service service-name for IMSID logical-IMS-identifier has been added.
|
|
|
Description:
|
The ADD SERVICE operator command for a local service has completed successfully.
service-name is the local service name which is passed to IMS as the transaction name.
logical-IMSID-identifier is a symbolic name that uniquely identifies an IMS system definition. This name must match a logical IMS ID (IMSID) specified in a HOST, TYPE=IMS statement.
|
|
|
Action:
|
None.
|
|
|
Response:
|
None required.
|
|
BEA2116
|
Reserved for future use.
|
|
BEA2117I
|
IMS Host IMSID has been modified.
|
|
|
Description:
|
The MOD HOST operator command has completed successfully. IMSID is a symbolic name that uniquely identifies the IMS system definition.
|
|
|
Action:
|
None.
|
|
|
Response:
|
None required.
|
|
BEA2117I
|
IMS Host IMSID has been modified.
|
|
|
Description:
|
The MOD HOST operator command has completed successfully.
IMSID is a symbolic name that uniquely identifies the IMS system definition.
|
|
|
Action:
|
None.
|
|
|
Response:
|
None required.
|
|
BEA2118E
|
IMS Host must be stopped prior to modifying.
|
|
|
Description:
|
The STOP HOST command must be issued before entering the MOD HOST command.
|
|
|
Action:
|
The MOD HOST command is aborted.
|
|
|
Response:
|
Enter the STOP HOST command and then retry the M |